Medium accuracy operational amplifier with built in frequency compensation and input protection from short-circuit.
Case types
K140UD7 – 301.8-2, mass not more than 1.5 g
KR140UD7 – 201.14-1
KR140UD608 – 2101.8-1
KF140UD7 – 4303.8-1
KB140UD7 – uncased
Electrical parameters
Power supply voltage, V | ±15±10% |
Common-mode input voltage range (at power supply voltage ±15 V), V | ±12 |
Maximum output voltage (at power supply voltage ±15 V, input voltage ±0.1 V, load resistance 2 kOhm) | ±10.5 |
Offset voltage (at power supply voltage ±15 V, load resistance 2 kOhm), not more than, mV K140UD7, KR140UD7, KR140UD708 KF140UD7 | 9 6 |
Input current (at power supply voltage ±15 V, load resistance 2 kOhm), not more than, nA | 400 |
Input current difference (at power supply voltage ±15 V, load resistance 2 kOhm), not more than, nA | 200 |
Current consumption (at power supply voltage ±15 V, load resistance 2 kOhm), not more than, mA | 3.5 |
Voltage gain ratio K140UD7, KR140UD7, KR140UD708 KF140UD7 | 3000 2500 |
Input resistance, not less than, Ohm | 400 |
Operational limits
Power supply voltage, V | ±(5..17) |
Common-mode input voltage, V | ±12 |
Differential input voltage, not more than, V | 24 |
Maximum output short-circuit time, s at -45..+35 oC at +35..+85 oC KF140UD7 at -10..+70 oC | unlimited 60 5 |