Angular rate sensor, which converts angular position of shaft to a correspondent DC voltage, sign depending on the direction.
Technical parameters
Angular rate range, o/s | ±6; ±12; ±18; ±30; ±60; ±90; ±120; ±180 | |
Power supply for continuous operation sensors three phase sinusoidal voltage, V frequency, Hz | 32.4..37.8 400±20 | |
Power supply for short-term operation sensors three phase rectangularvoltage, V frequency, Hz DC voltage, V | 20±2 400±20 ±15±1.5 | |
Power consumption ±15 V circuit, mA 20 V circuit, A 36 V circuit, A | 125 0.4 0.22 | |
Output voltage range, V | ±5 | |
Output curve inaccuracy, not more than | ±2% | |
Sensor threshold, not more than for ranges up to 30 o/s for ranges 60..180 o/s | 0.02% 0.05% | |
Zero-rate output, depending on range, V | 0.03..0.75 | |
MTTF, h for short-term operation sensors for continuous operation sensors | 1000 10000 | |
Specified life, h for short-term operation sensors for continuous operation sensors | 200 6000 | |
Lifetime, years | 13.5 | |
Ambient air temperature, oC | -60..+70 | |
Dimensions, not more than, mm | 67x62x52 | |
Mass, not more than, g | 350 |