* Pictures are placed for illustration purpose only. Appearance of real component may differ
DC milliammeter/microammeter for application in measurement and testing equipment and equipment, working infield environment at increased mechanical impacts and climatic loads.
Main parameters
M1360 DC milliammeters/microammeters are based on permanent magnet metering system. Moving element is suspended on tie-rods, with a mechanical countertorque. Device is impact- and vibration-proof. Operating positions: vertical and horizontal.
Accuracy class | 2.5 |
Vibration resistance frequency, Hz acceleration, m/s2 frequency, Hz acceleration, m/s2 |
10..30 15 10..51 30 |
Vibration stability frequency, Hz acceleration, m/s2 |
10..80 30 |
Impact resistance, acceleration, m/s2 | 750 |
Ambient air temperature, oC | -50..+80 |
Relative humidity at +40 oC | 98% |
Mass, kg | 0.45 |
Dimensions, mm | 60 x 60 x 82 |
Measurement range | Voltage drop at full-scale current | |
µA | mA | mV |
25-0-25 |
| 35 |
0-50 |
| 70 |
50-0-50 |
| 25 |
0-100 |
| 50 |
100-0-100 |
| 22 |
0-200 |
| 44 |
200-0-200 |
| 16 |
0-300 |
| 105 |
0-500 |
| 40 |
500-0-500 |
| 12 |
| 0-1 | 24 |
| 1-0-1 | 12 |
| 0-2 | 24 |
| 2-0-2 | 17 |
| 0-5 | 40 |
| 5-0-5 | 30 |
| 0-10 | 60 |
| 10-0-10 | 60 |
-special scales are available on a separate request. It marked by index i.e. M1360-7.
Annotation example: “Device M1360, 500 µA, 30 Hz, TU 25-05-117-77”