3V200K
Sealed switch for DC and AC circuits with inductive and noninductive loads.
Annotation breakdown:
3 – number of poles
V – switch
200 – conventional characteristic
K – place of installation: no letter – cabins with regular lighting, K – cabins with red lighting.
Operational conditions
Climate version | general |
Ambient air temperature, oC | -60..+60 |
Switches are operational after being in off-state at +80 oC for 2 hours | |
Relative humidity at +40 oC | 98% |
Diminished air pressure, kPa (mmHg) | 1.14 (8.56) |
Vibratory loads frequency, Hz acceleration, g | 5..300 5 |
Mechanical impacts acceleration, g frequency, min-1 | 4 40..100 |
Linear acceleration, g | 9 |
Switches are dust- and moistureproof |
Technical parameters
Rated voltage, V DC AC (320..1050 Hz, cos ?= 0.5..-1) AC (50 Hz) | 27 36 380 |
Switching current, A DC, noninductive load, 27 V DC, noninductive load, 36 V DC, τ≤0.015 s, 27 V DC, τ≤0.015 s, 36 V AC, 200 V AC, 115 V AC, 36 V AC, 380 V | 0.1..10 15 0.1..3 7 0.1..2.5 0.1..5 0.1..10 10 |
Operating mode | continuous |
Voltage drop at terminals, not more than, mV | 180 |
Actuation force, N (kgf) | 6.9..24.5 (0.7..2.5) |
Mass, not more than, g | 100 |
Warranty, years | 8 |
Switching modes
Version | Switching | Current type | Load type | Switching frequency, not more than, Hz | Number of switching cycles | ||
current, A | voltage, V | Total | incl. at maximum temperature | ||||
RX4.506.100 | 0.2..5 | 10..250 | DC | noninductive | 2 | 2.5?105 | 6.25?104 |
RX4.506.102 | 20..250 | AC 50 Hz | |||||
RX4.506.103 | |||||||
RX4.506.104 | 0.1..0.15 | 10..34 | DC | τ≤0.015 | 1 | 1?105 | 2.5?104 |
RX4.506.105 | 0.1..1 | ||||||
RX4.506.106 | 1..2 | 16?103 | 4?103 | ||||
RX4.506.107 | 0.2..2.5 | 20..250 | AC 50 Hz | cos ?> 0.3 | 1?105 | 2.5?104 | |
RX4.506.108 |