Circuit breaker designed to protect DC and AC circuits from current overloads (unacceptable duration or current) and short-circuit currents.
Operation principle is the following: under the overloading current, the bimetal strip bends by temperature and drive the release mechanism, which breaks the circuit.
The circuit breaker assembly can operate either as a manual switch or as an automatic circuit breaker with bimetal release.
Main parameters
Rated voltage at frequency 400±20 Hz and cos ?≥ 0.5, not more than, V | linear 200 (+7.0/-13.0) phase to neutral 115 (+4.0/-7.0) | ||||||||||||
Rated current, A | 1; 2; 3; 5; 7,5; 10; 15; 20; 25; 30; 35; 40; 50 | ||||||||||||
Cut-off currentmultiplicator at +20 ± 5 °C, not more than for 1 A circuit breaker for 2 A circuit breaker for 3-5 A circuit breaker for 7.5-15 A circuit breaker for 20-50 A circuit breaker |
| ||||||||||||
Cut-off current multiplicatorat -60 ± 3 °C, not more than for 1 A circuit breaker for 2 A circuit breaker for 3-5A circuit breaker for 7.5-50A circuit breaker |
| ||||||||||||
Thermal release cut-off time, min, not more than for A3K3-1-15 for A3K3-20-50 | 30 50 | ||||||||||||
Relative humidity at +40 oC | 98% | ||||||||||||
Ambient air temperature, oC | -60..+60 | ||||||||||||
Warranty, years | 10 | ||||||||||||
Mass, not more than, g | 140 |