Miniature contactor – 2-position electromagnetic device for remote switching of high-power electrical loads.
Technical parameters
Rated contact circuit current, A | 400 |
Rated coil voltage, V | 27 |
Rated coil current, A | 0.4 |
Number of contacts | 1 NC |
Contact inductive load, s | 0.003 |
Auxiliary output current, not more than, A | 4 A |
Contact resistance, not more than, mOhm | 30 |
Pick-up voltage, not more than, V | 18.9 |
Drop-out voltage, not more than, V | 8.1 |
Mechanical durability, cycles | 100 000 |
Number of switching cycles | 50 000 |
Insulation resistance, not less than, MOhm | 100 |
Insulation strength between contacts, VAC | 2000 |
Insulation strength between coil and contacts, VAC | 1500 |
Ambient air temperature, oC | -60..+50 |
Maximum allowed relative humidity at +40 oC | 98% |
Maximum altitude, m | 20 000 |
Mounting point vibration frequency, Hz acceleration, g | 10..200 ≤3.5 |
Landing impact frequency, min-1 acceleration, g | 60..100 4 |
Linear acceleration, g | 8 |
Precious metal content | silver – 15.58000 g |