Immediate action switches “Tumbler” type are designed for commutation of electric circuits of direct and alternate current in radio-electronic equipment.
Tumblers are designed in all-climatic modification.
Tumblers are manual control devices.
Constructive modifications:
- PT2-10V – handle fixing in two end points and mid position;
- PT2-20V – handle fixing in one end and mid positions;
- PT2-30V – handle fixing only in mid position;
- PT2-40V – handle fixing in two end positions (without mid position).
Basic technical and operational characteristics of tumblers: | |
Contact resistance, maximum, Om | 0,02 |
Isolation electric strength, V | 1500 |
Switching force, N: | from5,88 to 34,34 |
Isolation resistance, MOm, minimum | 1000 |
High operating temperature, °C | 100 |
Low operating temperature, °C | -60 |
High relative humidity at 35°C, % | 98 |
Warranty period: | 15 |
Electric modes of tumblers commutation: | ||||||||
Tumbler part type | Current type | Load type | Voltage, V | Current, А | Max commutated power, Vt (VхА) | Switching cycles quantity | ||
min | max | min | max | |||||
PT2-10V | Direct | Active | 3 | 16 | 0,01 | 16 | 256 | 15000 |
Direct | Inductive | 3 | 16 | 0,01 | 16 | 256 | 7500 | |
Direct | Active | 3 | 30 | 0,01 | 15 | 450 | 15000 | |
Direct | Inductive | 3 | 30 | 0,01 | 15 | 450 | 7500 | |
Alternate | Active | 3 | 40 | 0,01 | 16 | 640 | 15000 | |
Alternate | Inductive | 3 | 40 | 0,01 | 16 | 640 | 7500 | |
Alternate | Active | 3 | 127 | 0,01 | 10 | 1270 | 15000 | |
Alternate | Inductive | 3 | 127 | 0,01 | 10 | 1270 | 7500 | |
Alternate | Active | 3 | 240 | 0,01 | 5 | 1200 | 15000 | |
Alternate | Inductive | 3 | 240 | 0,01 | 5 | 1200 | 7500 | |
Alternate | Active | 3 | 380 | 0,01 | 5 | 1900 | 3000 | |
Alternate | Inductive | 3 | 380 | 0,01 | 2,5 | 950 | 7500 |