Home  /  Products  /  Switching devices  /  RES-55B RS4.569.600.0701

RES-55B RS4.569.600.0701

* Pictures are placed for illustration purpose only. Appearance of real component may differ.

The RES55 relay is dust-mist protected, hermetically sealed, monostable, intended for switching electrical circuits of direct and alternating current with a frequency up to 10 kHz.

The RES55 relay meets the requirements of GOST 16121-86 and technical specifications RS0.456.011TU.

Operational conditions.

Environment temperature from —60 to +85°С, for the RS4.569.600-12 design version from -60 to +70°С.

Cyclic temperature exposure from —60 and +70°С.

Increased relative humidity up to 98% at temperature +35°С.

Atmospheric pressure from 666 to 305900 Pa.

Sinusoidal vibration (vibration strength and vibration resistance) in the frequency range: from 5 to 50 Hz — at amplitude not more than 2.5 mm; from 50 to 3000 Hz — with acceleration not more than 250 m/s².

Shock strength.

For single shocks with acceleration not more than 1500 m/s² — 9 shocks. For multiple shocks with acceleration not more than 750 m/s² — 4000 shocks, with acceleration not more than 350 m/s² — 10000 shocks.

Impact resistance — with acceleration not more than 750 m/s².

Permanently acting linear accelerations not more than 500 m/s².

Modes of operation of the relay

Environment temperature,°С

Atmospheric pressure, Pa

The continuous dwell time of the coil under voltage, h

-60…+70

828 — 1066

150

-60…+85

50

-60…+70

6.66

Technical specifications.

Coil's power current — direct.

Insulation resistance between current-carrying elements, between current-carrying elements and the housing, MΩ, not less than:
in normal climate environment (coil de-energized).............................................................................................. 500
in high humidity conditions:
between current-carrying elements and housing, between contacts and coil ................................................................................................................... 5
between contacts................................................................................................... 10
at maximum temperature (after holding the coil under working voltage).................................................................................................. 200

Test alternating voltage between current-carrying elements ( excluding the contacts), between current-carrying elements and housing, V:
in normal climate environment.......................................................................................... 500
in high humidity conditions.............................................................................................. 200
at reduced atmospheric pressure................................................................................................. 200

Test alternating voltage between contacts of RES55A relay of versions RS4.569.600-00 — RS4.569.600-04, RS4.569.600-13 — RS4.569.600-17 amounts to 150 V, of versions RS4.569.600-05 — RS4.569.600-12 — 125 V; of RES55B relay of versions RS4.569.625-00 — RS4.569.625-04, RS4.569.625-10 — RS4.569.625-14 — 150 V, of versions RS4.569.625-05 — RS4.569.625-09 — 125 V.

Electrical capacitance, pF, not more than:
between normally closed contact 1 and spring 2................................................................................................................. 5
between normally open contact 3 and spring 2................................................................................................................. 2
between the casing 0 and coil A B............................................................................................................... 85
between the casing 0 and normally open contact 3................................................................................................................. 4
between the casing 0 and normally closed contact 1................................................................................................................. 5
between coil AB and normally open contact 3................................................................................................................. 3
between coil AB and normally closed contact 1................................................................................................................. 4

The relay's response time at nominal voltage is 1.5 ms. Release time is 2.3 ms.

Modes of operation of the relay are listed in the table above. Wear resistance — in the table below. Material of the contacts — Au 999.9, Rh 99.9. Electrical contact resistance is 0.18 Ohm. Relay mass is not more than 6 g.

Design version

Switching mode

Type of load

Current type

Frequency of operations , Hz, not more than

Number of operating sequences

Switching power, W

Current-carrying capacity, А

Open contacts voltage, V

total

including at maximum temperature

RS4.569.600-00

RS4.569.600-01

RS4.569.600-04

RS4.569.625-00

RS4.569.625-01

RS4.569.625-04

5·10-6-10-2

5·10-2-6

resistive

direct alternating

50

2·106

106

7.5

10-2-6·10-2

6 — 127

106

5·105

10-2-25·10-2

6 — 36

direct

alternating

5·105

2.5·105

15

25·10-2-5·10-1

direct alternating

10

104

103

5·103

5·102

10-2-15·10-2

inductive, t ≤ 0.015 s

direct

50

106

5·105

10-2-10-1

resistive

alternating

RS4.569.600-13

RS4.569.600-17

RS4.569.625-10

RS4.569.625-14

30

0.5 — 1.0

6 — 36

resistive

direct alternating

1

103

5·102

15

7.5

0.25 — 0.5

0.01 — 0.25

alternating

10

50

104

106

5·103

5·105

RS4.569.600-05

RS4.569.600-12

RS4.569.625-05

RS4.569.625-09

5·10-6-10-2

5·10-2-6

resistive

direct alternating

50

2·106

106

7.5

10-2-25·10-2

6 — 36

direct

106

5·105

alternating

5·105

2.5·105

15

25·10-2-5·10-1

direct alternating

10

104

103

5·103

5·102

10-2-15·10-2

inductive, t ≤ 0.015 s

direct

50

106

5·105

10-2-5·10-2

resistive

alternating

7.5·105

3.75·105

You can order RES-55B RS4.569.600.0701 from us