RS400
Electromagnetic DC starter relay, designed to turn on internal combustion engine starter.
Technical parameters
Operating voltage, V | 27+2/-5 |
Load current, A | 800 |
Operating mode | intermittent |
Design | enclosed, dust- and splash proof, shielded |
Operating position | any |
Turn-on voltage, V | 9..14 |
Turn-off voltage, V | 1..4 |
Armature full travel, mm | 13..15 |
Armature overtravel, mm | 2.5..4 |
Dimensions, mm | 142x132x220.5 |
Mass, kg | 7.1 |
Durability, number of cycles at 800 A at 1800 A | 400 100 |