Mechanical contactor switch for DC (with voltage up to 30 V) and AC (with voltage up to 220 V) circuits. Can be used in all climate conditions (including tropical) and on exposure to mechanical impacts.
Annotation breakdown
Annotation example – TKD511ODL
T – control coil circuit rated voltage (24...30V)
K – name of the device (contactor)
D – switching current multiplier, x10
5 – switching current, A (considering multiplier)
1 – number of independent normally closed contacts
1 – number of independent normally open contacts
O – maximum ambient air temperature, +85 oC
D – type of operation (D – continuous operation K- short-time operation )
L – additional design variations ( B – presence of auxiliary contacts; L – lightweight)
Technical parameters
Contactor version | Switching voltage, V | Switching current, A | Control circuit voltage, V | Number of switching circuits | Mass, kg | |
DC | AC | |||||
TKD103ODL | 24-30 | 110-210 | 1-10 | 24-30 | 3 | 0.12 |
TKD133ODL | 24-30 | 110-210 | 1-10 | 24-30 | 3 | 0.16 |
TKD203ODL | 24-30 | 110-210 | 2,5-25 | 24-30 | 3 | 0.205 |
TKD233ODL | 24-30 | 110-210 | 2,5-25 | 24-30 | 3 | 0.3 |
TKD503ODL | 24-30 | 110-210 | 5-50 | 24-30 | 3 | 0.41 |
TKD533ODL | 24-30 | 110-210 | 5-50 | 24-30 | 3 | 0.58 |
TKD511ODL | 24-30 | 110-210 | 5-50 | 24-30 | 3 | 0.25 |