TV1-2
Toggle switch for DC and AC circuits of communications electronics equipment.
Climate versions: all-climate, boreal.
Actuation: manual.
Mounting method: wire mounting.
Protector available separately.
The switch is two-pole, has NC contacts 1-2 and 3-4, and NO contacts 5-6 and 7-8.
Main technical parameters
Contact resistance, not more than, Ohm | 0.01 |
Insulation strength, V | 1100 |
Insulation resistance, not less than, MOhm | 1000 |
Actuation force, not more than, N | 3.9..14.7 |
Ambient air temperature, oC | -60..+85 |
Relative humidity at +35 oC | 98% |
Lifetime within warranty term, h | 10000 |
Mass, g | 40..50 |
Switching modes
Version | Current type | Load type | Voltage, V | Current, A | Maximum switching power, W | Number of switching cycles in normal conditions | ||
not less than | not more than | not less than | not more than | |||||
TV1-2 TV1-2V | DC | noninductive | 1.6 | 220 | 0.001 | 5 | 250 | 10000 |
DC | noninductive | 1.6 | 220 | 0.001 | 5 | 250 | 10000 | |
AC | noninductive | 1.6 | 220 | 0.001 | 5 | 250 | 10000 | |
AC | noninductive | 1.6 | 220 | 0.001 | 5 | 250 | 10000 |