V1-0.1/40
High-voltage kenotron for usage in continuous and pulsed modes.
Cathode: thoriated carbonized tungsten filament
Case type: glass with base
Mass: 150 g.
Electrical parameters
Filament voltage, V | 5 |
Filament current, A | 6±0.5 |
Emission current, not less than impulse*, A at filament voltage 3 V, mA | 2 30 |
Anode current**, not less than, mA | 75 |
Durability, not less than, h | 500 |
Durability criteria: emission current at filament voltage 3 V, not less than,mA | 15 |
*at filament voltage 5.5 V, anode impulse voltage 4 kV, impulse duration 5..10 mks, pulse ratio 50 Hz
**at anode voltage 200 V
Operational limits
Filament voltage, V | 4.75..5.25 |
Maximum reverse voltage, kV | 40 |
Maximum anode power dissipation, W | 75 |
Maximum anode impulse current, mA | 750 |
Maximum rectified current, mA | 100 |
Cathode warm-up time,s | 5 |
Environmental resilience
Ambient air temperature, oC | -60..+70 |
Relative humidity at +40 oC | 95..98% |
Air pressure | 3atm..400 mmHg |
Vibratory loads frequency, Hz acceleration, g | 15 5 |
Single mechanical impact acceleration, g | 5 |
Shelf life
In a warehouse | 12 years |
incl. in unsheltered conditions installed into equipment or within a spare parts kit, protected from direct sun exposure and moist | 3 years |
or installed into sealed equipment or within a sealed spare parts kit | 6 years |