Connector 2RM39KPE45G2V1 is cylindrical nonhermetic low frequency designed for work in electric circuits of direct and alternate current with frequency up to 3 Mhz and voltage up to 700V.
Connectors consist of two parts: plug and socket. Plugs and sockets can be block or cable.
Block part of connectors is produced without nipples or with straight nipples, cable part without nipples, with straight or angle nipples.
Contacts cover – gold or silver.
Wiring method – soldering.
Connectors are designed for wiring with shielded or unshielded cables thus nipple end nut changes.
Connectors are designed for interior and outer wiring in all-climatic modification.
Basic technical characteristics of connectors 2RM:
General characteristics of connectors 2RM: | |
Connector type | Non-hermetic |
Climatic modification | All-climatic |
Conventional body size | 14, 18, 22, 24, 27, 30, 33, 36, 39, 42 |
Connector constitution | Plug, socket |
Body type | Block, cable |
Installation part modification | Without nipple, with straight nipple, with angle nipple |
Coupling type | threaded |
Contacts cover | Gold, silver |
Wiring method | Dimensional, soldering |
Wiring | interior |
Technical parameters of connectors 2RM: | |
Contacts total quantity | 4, 7, 10, 19, 20, 22, 24, 30, 32, 45, 50 |
Maximum current on single contact, А: | |
Contacts resistance, maximum, MOm: | |
Maximum operating voltage, V | 560; 700 |
Maximum operating frequency, MHz | 3 |
Capacitance between contacts, maximum, pF | 6 |
Isolation resistance in normal climatic conditions, minimum, MOm: | 5000 |
Sinusoidal vibration, frequency range, Hz: | 1....5000 |
Sinusoidal vibration, acceleration, m/s2(g): | 490 (50) |
Mechanical impact, single action with acceleration, m/s2(g): | 5000 (500) |
Mechanical impact, repeated operation with acceleration, m/s2(g): | 1000 (100) |
Low atmospheric pressure, Pa: | 133,32·10-12(10-12) |
High atmosphericpressure, Pa: | 50,6·104(5,0) |
High relative humidity at temperature +40°C: | 98% |
Environment operating temperature, °C: | from-60 up to+100 |
Minimum service hours,h: | 1000 |
Maximum coupling – parting number | 500 |
Shelflife, years | 15 |