Wires, connectors
Connector 2RMD45B50SH8V1 is cylindrical low frequency small scale designed for work in electric circuits of direct and alternate current with frequency up to 3 MHz and voltage up to 700V.
Connectors 2РМДconsist of two parts – plug and socket which can be either block or cable.
Block part of connectors is produced without nipple or with straight nipples, cable part – without nipples, with straight or angle nipples.
Connectors coupling – threaded, casing polarization – single splined.
Contacts cover – gold or silver.
Connectors are designed for wiring with shielded or unshielded cables (wires) thus nipple end nut changes.
Connectors2RMD are designed for interior wiring in all-climatic modification.
Basic technical characteristics of connectors 2RMD:
General characteristics of connectors 2RMD: | |
Connector type | Non-hermetic |
Conventional casing size | 18, 24, 27, 30, 33, 36, 39, 42, 45 |
Connector constitution | Plug, socket |
Casing type | Block, cable |
Installation element modification | Without nipple, straight, angle |
Shielded or unshielded | shielded |
Coupling type | threaded |
Contacts cover | Gold, silver |
Wiring method | Dimensional, soldering |
Wiring | interior |
Technical parameters of connectors 2RMD: | |
Total quantity of contacts | 4, 7, 8, 10, 19, 20, 22, 24, 32, 45, 50 |
Maximum current on single contact, А: | |
Contacts resistance, maximum, MOhm: | |
Maximum operating voltage, V | 560; 700 |
Maximum operating frequency, MHz | 3 |
Isolation resistance in normal climatic conditions, minimum, MOhm | 5000 |
Sinusoidal vibration, frequency rangeHz | 1....5000 |
Sinusoidal vibration, acceleration, m/s2(g): | 490 (50) |
Mechanical impact, single action with acceleration, m/s2(g): | 5000 (500) |
Mechanical impact, repeated operation with acceleration, m/s2(g): | 1000 (100) |
Minimum service hours, h: | 1000 |
Coupling – parting maximum quantity | 500 |
Shelf life, years | 15 |
Lowatmosphericpressure, Pa | 133,32·10-12(10-12) |
Highatmosphericpressure, Pa | 50,6·104(5,0) |
High relative humidity at temperature +40°C: | 98% |
Environment operating temperature, °C: | from-60 up to+100 |