47K SOCKET CONNECTOR
Designed for connection of portable receivers of direct current with voltage up to 36 V, built in mobile means of land, water and air transport. The acceptance code is "1", and "3".
47K Socket connector is a two-contact cylindrical connector that operated in DC electric circuits with voltage up to 36 V. 47K Socket connectors are suitable for operation in conditions of moderate cold and tropical climate.
Main technical characteristics of 47-K Socket Connector :
- IP00;
- Maximum operating voltage ...... 36 V;
- Sinusoidal vibration:
- frequency range ...... 1-80 Hz;
- acceleration amplitude ...... 150 m/s2;
- Number of connections/disconnections ...... 10000;
- Operating temperature range ...... from -60 to +110 °С;
- Minimum service life ...... 8 years;
- Minimum life span ...... 10 years.
Parameter and Characteristics Description | Value |
MaximumDCvoltageataratedcurrent 6,3 per contact | 36 V |
Rated operational current per contact | 6,3 A |
Ensures certain polarity of a plug and socket connector | |
Maximum weight | 28 gram |
Withdrawal force, N | 0, 5 - 8,0 |
Itispossibletoconnectexternalconductors (copper stranded) with a cross section,mm2 | 1 - 1,5 |
Canoperate at loads up to 10 A at a nominal voltage of 12 V | |
Electrical Parameters: | |
Maximum permissible current per each contact is 10 A at a nominal voltage of 12 V | |
Electrical strength of insulation of current-carrying parts of connectors in both cold and heated, up to the established operating temperature, state must, for 1 minute, withstand the test voltage of alternating current at frequency 50 Hz: - at normal values of climatic factors of the environment, V - after stay in a chamber with a relative air humidity of 95 ± 3% at a temperature of 35 ° C for at least 96 hours, V - intheheatedstate, V | |
1 000 | |
500 | |
500 | |
Mechanical Environment Stability: | |
Vibration resistance of attachment points with frequency up to 80 Hz with acceleration no more than, m/s2 | 98,1 |
Vibration resistance of attachment points with frequency up to 80 Hz with acceleration no more than, m/s2 | 29,43 |
Shocks with acceleration, at a frequency of 80 beats per minute, m/s2 | 117,72 |
Any working position is allowed | |
Climatic Environment Stability: | |
Upper value of the working temperature of the external environment,0С | 60 |
Upper value limit of ambient temperature with short-term, no more than 2 hours, exposure with disconnected load,0С | 80 |
Lower value of the working temperature of the external environment,0С | - 60 |
Upper operating value of atmospheric pressure, mm Hg | 800 |
Average operating value of atmospheric pressure, mmHg | 308 |
Reduced value limit of atmospheric pressure for short-term, no more than 0.5 h, operation, mmHg | 5 |
Upper value of the relative humidity of air at a temperature of up to 35 ° C for at least 96 hours, % | 95±3 |
Atmospheric condensed precipitation (frost and dew) | + |
Salt fog, mold fungi, dust, and solar radiation (versionВ) | + |