Electrical low frequency rectangular connectors, type 6R
Connectors are intended for direct current, alternating current (up to 3 MHz of frequency) and impulse current electrical circuits.
Annotation breakdown
Cable (unit) plug (socket) 6R-100(150)A(V) IYu0.364.030 TU, where
6R – type of the connector;
100 (150) – number of contacts;
A (V) – type of contact plating:
A – gold; V – silver;
IYu0.364.030 TU – code of technical specifications.
Climate version – NF (moderately cold climate) according to GOST V 20.39.404-81
Operational conditions
Sinusoidal vibration (for unit connectors): frequency range, Hz amplitude of acceleration, m/s2 (g) frequency range, Hz amplitude of acceleration, m/s2 (g) | 5 – 200 100 (10) 200 – 2500 25 (2.5) |
Acoustic noise: frequency range, Hz sound pressure level, dB | 50 – 10000 130 |
Repeated mechanical shock (for unit connectors): shock acceleration peak value, m/s2 (g) duration of shock, ms | 350 (35) 1 – 80 |
Diminished operating air pressure, Pa (mmHg) | 0.67·103 (5) |
Elevated operating temperature, °C | 85 |
Diminished operating temperature, °C | minus 60 |
Temperature change, °C | 115 to minus 60 |
Elevated relative air humidity at 40°C (for unit connectors), % | 98 |
Frost and dew, mold fungi, solar irradiation, salt fog | |
Connector (plug and socket) wiring tails are supposed to allow connection of max wire gauge, mm2 | 0.5 |
Technical parameters
Current, A | 2 |
Voltage, V (ampl.) | 115 |
Contact resistance, mOhm, not more than | 15 |
Insulation resistance, mOhm, not less than | 1000 |
Capacitance between any pair of contacts, pF, not more than | 6 |
Insulation strength, V (ampl.) | 500 |
Сontact withdrawal force with reference gauge, N (kgf), not less than | 0.15 (0.015) |
Unit connector withdrawal force, N (kgf), not more than | 150 (15) |
Lifelength, h | 1500 |
Number of connection-disconnection cycles | 500 |
Minimum shelf life,years | 25 |