* Pictures are placed for illustration purpose only. Appearance of real component may differ
Quick-connect connectors for DC and AC (up to 3 MHz) circuits.
Connectors consist of 2 parts: a plug and a socket (both cable-side or unit-side). Plugs come in sealed and non-sealed version, sockets – in non-sealed version.
Connectors come with no shell, open-type shell, enclosed-type shell (with or without protective sleeve). Connectors have a rubber insulator that protects the mounting area from the environment.
Joining method: bayonet, with multiple keys.
Contact plating: gold.
Connectors are for inner mounting, climate version: all-climate
Annotation breakdown
Annotation example: RBM4 – N 4 Sh(G) 1(2, 3, 6, 7) – 5 W
RBM4 – connector type
N – non-sealed unit-side plug
4 – number of contacts
Sh (g) – connector type: Sh – plug, G – socket
1(2, 3, 6, 7) – design: 1 – unit-side with no shell; 2 – unit-side with open-type shell and no sleeve; 3 – unit-side with enclosed-type shell and protective sleeve; 6 – cable-side with enclosed-type shell and protective sleeve; 7 – cable-side with open-type shell and no sleeve.
5 – unit-side with no rubber insulator; no symbol – with insulator
W – all-climate version
Annotation consists of a connector name (plug/socket), version code, technical requirement version.
Technical parameters
Contact resistance, mOhm contact diameter 1.0 mm contact diameter 1.5 mm contact diameter 2.0 mm | 5 2.5 1.6 |
Insulation resistance in normal conditions, MOhm | 5000 |
Air leakage speed at pressure difference 0.15 MPa (1,5 kgf/cm2) (for sealed plugs), not more than, l/h | 0.1 |
Number of connection-disconnection cycles | 1000 |
Minimum lifetime, h | 1000 |
Shelf life, years | 15 |
Connectors are resistant to special environment conditions (for GE0.364.196 TU version) |
Operational conditions
Sinusoidal vibration frequency, Hz acceleration, m/s2 (g) | 1..5000 300 (30) |
Single mechanical impact acceleration, m/s2 (g) | 1500 (150) |
Multiple mechanical impacts acceleration, m/s2 (g) for connectors for unit-side plug | 400 (40) 1500 (150) |
Ambient air temperature, oC | -60..+100 |
Diminished air pressure, Pa (mmHg) | 1.3·10-10 (10-12) |