*Pictures are placed for illustration purpose only. Appearance of real component may differ.
Miniature rectangular low-frequency single (SNP336) and double (SNP337) connectors for DC, AC (up to 3 MHz) and impulse circuits.
Connectors consist of plugs and sockets, with straight case, housings for case mounting or with no case
Connection type: cut-in
Connectors are couplable with low-frequency connectors RPKM1-4
Contact plating: gold, silver
Climate version: all-climate, for inner mounting
Annotation breakdown
SNP337-26 V(R) P1 1(2) 1(7)
SNP336 – connector type: SNP336 – single, SNP337 – double
26 – number of contacts
V(R) – V – plug; S – socket
P – mounting method: soldering, 1 – terminal for wire mounting
1(2) – contact plating: 1 – gold, 2 – silver
1 – case type: 1 – unshielded straight case, 7 – connector body with housings for case mounting, no symbol – no case or housings.
Notes:
SNP 336 with silver plated contacts can have 26, 38, 45, 57, 67 contacts; with gold plated contacts 45, 57, 67 contacts.
SNP337 can have any contact pair layout
Number of contacts for single connector is represented by an even number, for double connector – by a fraction. In case any part of double connector is missing, the representing part of a fraction will be replaced by “S”. Customer can install any other connector instead of missing part, considering that uncoupling force in such case should not exceed 196 N (20 kgf)
Main technical parameters
Contact resistance, mOhm silver plated contacts (diameter 1.0 mm) gold plated contacts (diameter 1.5 mm) |
|
Insulation resistance at operational voltage, MOhm 100 V more than 100 V |
|
Current per contact, A diameter 1.0 mm diameter 1.5 mm |
1.6 (SNP336), 1.3 (SNP337) 7.0 (SNP336), 6.0 (SNP337) |
Maximum current per contact, A diameter 1.0 mm diameter 1.5 mm |
4.0 8.0 |
Minimum shelf life, years | 20 |
Number of connection-disconnection cycles | 500 |
Connectors are resistant to special factors |
|
Minimum lifetime depending on maximum temperature
Minimum lifetime, h | Maximum temperature, oС |
15000 | 94 |
20000 | 90 |
25000 | 86 |
30000 | 84 |
40000 | 80 |
50000 | 77 |
80000 | 70 |
10000 | 68 |
Contact overheat depending on current load
Current load, % of maximum | Contact overheat, oC |
100 | 20 |
90 | 15 |
80 | 13 |
70 | 10 |
60 | 8 |
50 | 6 |
Operational conditions
Sinusoidal vibration frequency, Hz acceleration, m/s2 (g) | 5..2500 150 (15) |
Single mechanical impact acceleration, m/s2 (g) | 5000 (500) |
Multiple mechanical impacts acceleration, m/s2 (g) | 750 (75) |
Linear acceleration, m/s2 (g) | 1500 (150) |
Ambient air temperature, oC | -60..+100 |
Diminished air pressure, Pa (mmHg) | 1.3·10-4 (10-6) |
Electromechanical parameters
Contact layout | Contact diameter, mm | Number of contacts | Current per contact, A | Total current load, A | Contacts at maximum voltage | Maximum DC voltage or voltage amplitude (for AC or impulse), at given pressure, V | ||||
SNP336 | SNP337 | SNP336 | SNP337 | 2300..400 mmHg | 400..15 mmHg | 15..10-6 mmHg | ||||
1 | 1.5 | 26 | 3.7 | 3.0 | 100 | 82 | 1-5, 8-12, 15-19, 22-26 | 250 | 350 | 200 |
6, 7, 13, 14, 20, 21 | 800 | 400 | 300 | |||||||
2 | 1.5 | 38 | 3.3 | 2.6 | 130 | 105 | 1-68 | 350 | 250 | 200 |
3 | 10 | 45 | 1.6 | 1.3 | 75 | 60 | 1-6, 8, 9, 11, 12, 14-19, 21, 22, 24, 25, 27-32, 34, 35, 37, 38, 40-45 | 400 | 300 | 250 |
7, 10, 13, 20, 23, 26, 33, 36, 39 | 1000 | 500 | 300 | |||||||
4 | 1.0 | 57 | 1.6 | 1.3 | 90 | 75 | 1-57 | 400 | 300 | 250 |
5 | 1.0 | 64 | 1.2 | 1.0 | 100 | 82 | 1-10, 58-67 | 100 | 100 | 60 |
1.5 | 3 | 7.0 | 6.0 | 11-57 | 350 | 250 | 200 |