Dustproof, two-position, single-stable relay with four changeover contacts.
It is intended for switching of electric circuits of direct and alternating current.
Technical characteristics :
Modification | Coil resistance,Ohm | Current, mA | Rated voltage,V | Switching time, ms | Contact resistance, Ohm | Contacts material | ||
On | Off | On | Off | |||||
RF4.500.335-01 | 175 +35.0 -17.5 | 36 | 8 | 12±1,2 | 0,6 | Silver | ||
RF4.500.335-02 | 650+130-97,5 | 20 | 4 | 24±2,4 | ||||
RF4.500.335-03 | 700±105 | 21 | 3 | 30±3 | ||||
RF4.500.335-04 | 2500 +375-250 | 10,5 | 2,5 | 48±4,8 | 15 | 8 | ||
RF4.500.335-05 | 2800 +280-420 | 11 | 2 | 60±6 | ||||
RF4.500.335-06 | 650 +97,5 | 19 | 6 | 24±2,4 | 0,3 | Gold | ||
RF4.500.335-07 | 700±105 | 21 | 3 | 30±3 |
Wear resistance
Modification | Commutation mode | Load type | Current type | Switching frequency, Hz | Number of commutation cycles | ||
Allowed current, А | Open circuit voltage, В | ||||||
total | Incl. at max temperature | ||||||
RF4.500.335-01 RF4.500.335-02 RF4.500.335-03 RF4.500.335-04 RF4.500.335-05 | 0,03-0,05 0,05-0,10 | 30-60 | Active | DC | 5 | 10 6 5·10 5 | 2·10 5 10 5 |
0,10-0,30 0,10-0,30** | 12-60 60-220* | 3·10 5 10 5 | 6·104 2·104 | ||||
0,30-1,0 1,0-2,0 | 12-30 | 10 5 10 4 | 2·104 2·10 3 | ||||
2,0-3,0 | 1 | 5·10 3 | 10 3 | ||||
0,10-0,30 | 12-115* | AC 50-1000 Hz | 5 | 10 5 | 2·104 | ||
0,05-0,10 | 60-220* | ||||||
6-220 | DC | ||||||
0,05-0,15 | 6-30 | Inductive t < 15 ms | 2,5·104 | 5·10 3 | |||
0,15-1,0 | 1 | 2,5·103 | 5·10 2 | ||||
0,05-0,15 | 6-115 | cosΦ >0,3 | AC 50-1100 Hz | 2,5·104 | 5·10 3 | ||
0,15-0,50 | cosΦ> 0,5 | 5 | 10 4 | ||||
RF4.500.335-06 RF4.500.335-07 | 5·10-6 – 10-2 5·10-3 – 2·10-1 10-1– 5·10-1 | 0,05-30 0,50-30 1-15 | Active
| DC | 2·10 5 105 10 4 | 4·104 10 4 10 3 |
The minimum service life and shelf life:
- When stored in a heated storage environment, as well as installed in a protected equipment or in a set of spare parts - 12 years;
- When stored in an unheated storage, in the manufacturer's packaging and installed in the equipment - 2 years;
- When stored inside canopy, in the manufacturer's packaging and installed in the equipment - 1 year;
- When stored on an open platform, mounted on the equipment - 1 year.
Insulation resistance between live circuits, current-carrying circuits and housing,MΩ: - in normal climatic conditions: - in conditions of high humidity: - at the maximum temperature: | 200 3 20 |
Electrical strength of insulation under normal climatic conditions between current-carrying elements, current-carrying elements and housing, V: | 500 |
Vibration loads: - frequency range, Hz: - acceleration, m/s2: | 1500 30 |
Linear acceleration, m /s2 (g): | up to 150 |
Mechanical shock, single action with acceleration, m /s2: | 750 |
Mechanical shock, multiple action with acceleration, m /s2: | 250 |
Relative humidity at + 35 ° C: | up to 98% |
Atmospheric pressure, kPa: | from 0,6 to 104 |
Operating ambient temperature, ° C: | from -60 to +85 |
Weight, g: | 38 |
Minimum service life, years: | 12 |