RES-47 RF4.500.407-01.01 are hermetic, two-position, monostable relays of direct current designed for commutation of electric circuits of direct and alternate current with frequency 50-2500 Hz.
Technical characteristics of relays RES-47 RF4.500.407-01.01:
• winding resistance, Om ...... 157-181;
• seal-in current, mА...... 42;
• drop-out current, mA ...... 4;
• operating voltage, V ...... 10,8-13,2;
• isolation resistance between current conducting elements, current conducting elements and casing:
- in normal climatic conditions ...... minimum 200 MOm;
- in conditions of high humidity ...... minimum 10 MOm;
- at maximum temperature ...... minimum 50 MOm;
• electric strength of isolation in normal climatic conditions:
- between current conducting elements ...... minimum 350 V;
- between current conducting elements and casing ...... minimum 500 V;
• relay weight ...... 9 g.
Technical characteristics of relays RES-47:
Technical characteristics | Values |
Isolation resistance between current conducting circuits, current conducting circuits and casing, MOm: | |
Electric strength of isolation in normal climatic conditions between current conducting elements, current conducting elements and casing, V: | 500 |
Vibrational loads: | |
Relative humidity at temperature +35°C: | Up to98% |
Atmospheric pressure, Pa: | from 1,333х10-6up to 3,33х105 |
Environment operating pressure, °C: | from-60 up to+85 |
Relay weight, g: | 9,0 |
Minimum shelflife, years: | 12 |