Home  /  Products  /  Switching devices  /  RES-54 HP4.500.011.02

RES-54 HP4.500.011.02

RES-54 HP4.500.011-02 insulated, two-step, monostable relay of direct current designed for commutation of electric circuits of direct and alternate current with frequency 50-1100 Hz.


Operational conditions:
Environment temperature from -60 up to +125ºС, for relays HP4.500.035-01, HP4.500.035-02, HP4.500.036-01, HP4.500.036-02 from -60up to +85ºС.
Relative humidity up to 98% at temperature +35ºС.
Atmospheric pressure from 0,13•10-3 up to 297 kPa.

Technical characteristics of relays RES-54 HP4.500.011-02:
• winding resistance, Om ...... 3400-4600;
• seal-in current, mА...... 3,6;
• drop-out current, mА...... 0,4;
• operating voltage, V ...... 24-32;
• isolation resistance between current conducting elements, current conducting elements and casing:
- in normal climatic conditions, minimum ...... 200 MOm;
- in conditions of high humidity, minimum ...... 10 MOm;
- at maximum temperature, minimum ...... 20 MOm.
• electric strength of isolation in normal climatic conditions between current conducting elements, current conducting elements and casing ...... 500 V.
RES-54Аweight ...... 21 g.
RES-54B weight ...... 22 g.

Technical characteristics of relay RES-54:

Technical characteristics

Value


isolation resistance between current conducting circuits, current conducting circuits and casing MOm:
- in normal climatic conditions:
- in conditions of high humidity:
- at maximum temperature:


200
10
20

Electric strength of isolation between current conducting elements, V:

500

Electric strength of isolation between current conducting elements and casing, V:

500

Linear acceleration, m/s2(g):

Up to100

Mechanical impact, single action with acceleration, m/s2:

4000 (75)

Mechanical impact, repeated operation with acceleration, m/s2:

1000 (4000)

Relative humidity at temperature +35°C:

Up to98%

Atmospheric pressure, Pa:

from 1,33х10-6up to 3,04х105

Environment operating temperature, °C:

from-60 up to+85

Relay weight, g:

22,0

Minimum service life, years:

12

Basic electric parameters of relays RES-54:

Passport number of relay RES-54B

Contact groups quantity

Operating voltage

Winding resistance

Current

Time

Commutated

Seal-in

Drop-out

Seal-in

Drop-out

Current

Voltage

V

Om

mA

ms

ms

А

V

RES-54B HP4.500.010-02

1P

22…32

3400…4600

3,0

0,3

12,0

8,0

0,01...1,0

6…100

RES-54B HP4.500.011-02

2P

24…32

3400…4600

3,6

0,4

12,0

8,0

0,01...1,0

6…100

RES-54B HP4.500.012-02

2P

24…32

3400…4600

3,6

0,4

12,0

8,0

10-6...0,5

0,05...100

RES-54B HP4.500.013-02

1P

22…32

3400…4600

3,0

0,3

12,0

8,0

10-6...0,5

0,05...100

RES-54B HP4.500.035-02

2P

24…32

3400…4400

4,2

0,4

12,0

8,0

0,01...1,0

6…100

RES-54B HP4.500.036-02

2P

24…32

3400…4400

4,2

0,4

12,0

8,0

10-6...0,5

0,05...100

You can order RES-54 HP4.500.011.02 from us