Home  /  Products  /  Switching devices  /  RES-80 DLT4.555.014.03

RES-80 DLT4.555.014.03

Switching devices RES-80 DLT4.555.014.03
*Pictures are placed for illustration purpose only. Appearance of real component may differ.

Sealed monostable two-step relay with 2 switching contacts for DC and AC circuits.

Relay is compliant with GOST 16121-86 and DLT0.455.001 TU

Pick-up time not more than 5 ms, drop-out time not more than 3 ms.

Mass, not more than: RES80 - 2 g.; RES80-1 - 2.5 g

Operational conditions

Ambient air temperature

see below

Relative humidity at +35 oC

98%

Air pressure, Pa

1.33·10-6..3.04·10-5

Sinusoidal vibration

frequency, Hz

acceleration, m/s2

frequency, Hz

amplitude, mm

frequency, Hz

acceleration, m/s2

0.5..10

20

10..55

2

55..4000

200

Single mechanical impact (opening of NC contacts allowed, closing of NO contacts not allowed)

number of impacts

acceleration, m/s2

number of impacts

acceleration, m/s2

2

5000

9

1500

Multiple mechanical impacts

number of impacts

acceleration, m/s2

4000

750

Impact strength, m/s2

750

Linear acceleration, m/s2

1500

Acoustic noise

sound pressure, Pa

frequency, Hz

200

50..10000

Reliability criteria

Shelf life in heated storage or installed into protected equipment – 20 years

In an un-heated storage or under roof: in manufacturers package or installed into un-protected equipment – 10 years

Without roof: only installed into equipment or in a spare parts kit – 10 years

Annotation examples

Annotation

Relay version

DLT4.555.014-04

RES80 DLT0.455.001TU

DLT4.555.015-04

RES80-1DLT0.455.001TU


Technical parameters

Coil supply current

DC

Insulation resistance between live elements, live elements and case, not less than, MOhm

in normal conditions (coil in off-state)

at increased humidity

at maximum temperature (after coil being in on-state for at least 0.5 h)

200

10

20

Insulation strength between live elements, live elements and case, V

in normal conditions between live elements and case

in normal conditions between live elements

at increased humidity

at diminished air pressure

200

180

150

150

Relay operating modes

Version

Voltage, V

Ambient air temperature, oC

Air pressure, Pa

Coil on-state time

Pulse ratio

continuous

total, h

DLT4.555.014

DLT4.555.015

27±2.7

-60..+100

9.6·104..3.04·105

100 h

500

-

27+4.05/-2.7

2.7+5.4/-4.0

2.7+7/-4

-60..+85

-60..+70

-60..+55

800

27±2.7

27+4.05/-2.7

-60..+70

-60..+55

6.67·102..9.6·104

550

800

27±2.7

-60..+85

1.33·10-6..6.67·102

30 s

550

8

27+4.05/-2.7

27+5.4/-4.05

27+7/-4

-60..+70

-60..+55

-60..+40

800

27±2.7

-60..+85

-60..+70

8.4·104..3.1·105

100 h

500

1000

-

-60..+70

-60..+55

-60..+40

0.01..0.5 s

100 h

0.01..0.5s

1500

2000

500

20

20

DLT4.555.014-01

DLT4.555.015-01

15±1.5

15+2.3/-1.5

-60..+85

-60..+70

9.6·104..3.04·105

100 h

800

-

15+3.0/-1.5

15+3/-4

-60..+55

15±1.5

6.67·102..9.6·104

15+2.3/-1.5

-60..+40

-60..+55

1.33·10-6..6.67·102

30 s

8

15+3.0/-1.5

-60..+40

DLT4.555.014-02

DLT4.555-015-02

6.3±0.63

-60..+100

9.6·104..3.04·105

100 h

500

-

6.3+0.95/-0.63

6.3+1.26/-0.95

6.3+1.26/-1.15

-60..+85

-60..+70

-60..+50

800

6.3±0.63

-60..+70

6.67·102..9.6·104

550

6.3+0.95/-0.63

6.3+1.26/-0.95

-60..+55

-60..+40

800

6.3±0.63

-60..+85

1.33·10-6..6.67·102

30 s

550

-

6.3+0.95/-0.63

6.3+1.26/-0.95

6.3+1.26/-1.15

-60..+70

-60..+55

-60..+40

800

DLT4.555.014-03

DLT4.555-015-03

4±0.4

4+0.8/-0.4

-60..+85

-60..+70

9.6·104..3.04·105

100 h

800

-

4+1.0/-0.5

-60..+55

4±0.4

6.67·102..9.6·104

4+0.6/-0.5

-60..+40

4±0.4

4+0.8/-0.4

4+1.0/-0.5

-60..+70

-60..+55

-60..+40

1.33·10-6..6.67·102

30 s

8

DLT4.555.014-04

DLT4.555-015-04

3±0.3

3+0.45/-0.3

3+0.6/-0.45

-60..+85

-60..+70

-60..+55

9.6·104..3.04·105

100 h

800

-

3±0.3

3+0.45/-0.3

3+0.6/-0.45

-60..+70

-60..+55

-60..+40

6.67·102..9.6·104

3±0.3

3+0.45/-0.3

3+0.6/-0.45

-60..+70

-60..+55

-60..+40

1.33·10-6..6.67·102

30 s

8

DLT4.555.014-05

DLT4.555-015-05

27±2.7

-60..+100

9.6·104..3.04·105

100 h

500

-

27+4.05/-2.7

27+5.4/-4.05

27+7/-4

-60..+85

-60..+70

-60..+55

800

27+2.7

27+4.05/-2.7

-60..+70

-60..+55

6.67·102..9.6·104

550

800

27±2.7

-60..+85

1.33·10-6..6.67·102

30 s

550

8

27+4.05/-2.7

27+5.4/-4.05

27+7/-4

-60..+70

-60..+55

-60..+40

800

27±2.7

-60..+85

-60..+70

8.4·104..3.1·105

100 h

500

1000

-

27±2.7

-60..+70

-60..+55

-60..+125

0.01..0.5 s

100 h

0.01..0.5 s

15000

2000

500

20

-

20

DLT4.555.014-06

DLT4.555-015-06

15±1.5

15+2.3/-1.5

-60..+85

-60..+70

9.6·104..3.04·105

100 h

800

-

15+3.0/-1.5

15+3/-4

-60..+55

15±1.5

6.67·102..9.6·104

15+2.3/-1.5

-60..+40

-60..+55

1.33·10-6..6.67·102

30 s

8

15+3.0/-1.5

-60..+40

DLT4.555.014-07

DLT4.555-015-07

6.3±0.63

-60..+100

9.6·104..3.04·105

100 h

500

-

6.3+0.95/-0.63

6.3+1.26/-0.95

6.3+1.26/-1.15

-60..+85

-60..+70

-60..+55

800

6.3±0.63

-60..+70

6.67·102..9.6·104

550

6.3+0.95/-0.63

6.3+1.26/-0.95

-60..+55

-60..+40

800

6.3±0.63

-60..+85

1.33·10-6..6.67·102

30 s

550

8

6.3+0.95/-0.63

6.3+1.26/-0.95

6.3+1.26/-1.15

-60..+70

-60..+55

-60..+40

800

DLT4.555.014-08

DLT4.555-015-08

4±0.4

4+0.8/-0.4

-60..+85

-60..+70

9.6·104..3.04·105

100 h

800

-

4+1.0/-0.5

-60..+55

4±0.4

6.67·102..9.6·104

4+0.6/-0.5

-60..+40

4±0.4

4+0.8/-0.4

4+1.0/-0.5

-60..+70

-60..+55

-60..+40

1.33·10-6..6.67·102

30 s

8

DLT4.555.014-09

DLT4.555-015-09

3±0.3

3+0.45/-0.3

3+0.6/-0.45

-60..+85

-60..+70

-60..+55

9.6·104..3.04·105

100 h

800

-

3±0.3

3+0.45/-0.3

3+0.6/-0.45

-60..+70

-60..+55

-60..+40

6.67·102..9.6·104

3±0.3

3+0.45/-0.3

3+0.6/-0.45

-60..+70

-60..+55

-60..+40

1.33·10-6..6.67·102

30 s

8

Particular parameters

Version

Coil resistance, Ohm

Current, mA

Contact resistance, not more than, Ohm

Contact material

Pick-up, not more than

Drop-out, not less than

DLT4.555.014

DLT4.555-015

1700+255/-170

7.5

2.21

0.5

Gold-silver-magnesium-nickel

Gold

DLT4.555.014-01

DLT4.555-015-01

670±61

13

1.43

DLT4.555.014-02

DLT4.555-015-02

105±10.5

30

0.58

DLT4.555.014-03

DLT4.555-015-03

55±5.5

40

0.48

DLT4.555.014-04

DLT4.555-015-04

30±3

53

0.35

DLT4.555.014-05

DLT4.555-015-05

1700+255/-170

7.5

2.21

0.25

DLT4.555.014-06

DLT4.555-015-06

610±61

13

1.43

DLT4.555.014-07

DLT4.555-015-07

105±10.5

30

0.58

DLT4.555.014-08

DLT4.555-015-08

55±5.5

40

0.48

DLT4.555.014-09

DLT4.555-015-09

30±3

53

0.35

Durability

Version

Switching mode

Load type

Current type

Switching frequency, not more than, Hz

Number of switching cycles

Allowed current, A

Voltage on open contacts, V

total

incl. at maximum temperature

DLT4.555.014

DLT4.555.014-01.. DLT4.555.014-04

DLT4.555.015-01.. DLT4.555.014-04

0.01..0.25

0.25..0.50

6..36

Noninductive

DC

10

105

5·104

0.5·105

2.5·104

0.50..1.0

104

0.5·104

0.01..0.15

6..60

AC 50..10000 Hz

10

-

-

0.005..0.15

0.15..0.25

6..36

Inductive t≤0.015 s

DC

-

3

5·104

12.5·103

2.5·104

6.25·103

0.25..0.5

Inductive t≤0.005 s

1

5·103

2.5·103

DLT4.555.014-05..

DLT4.555.014-09

DLT4.555.015-05.. DLT4.555.015-09

5·10-6..0.01

0.05..10

Noninductive

DC

10

1.5·105

0.75·105

0.001..0.10

0.05..36

105

0.5·105

5·10-6..0.005

0.05..10

Inductive t≤0.015 s

-

0.001..0.10

0.05..36

Inductive t≤0.005 s

-

-

5·10-6..0.01

0.001..0.10

0.05..10

0.05..36

Noninductive

AC 50..10000 Hz

10

7

105

4·104

0.5·105

2·104

You can order RES-80 DLT4.555.014.03 from us