*Pictures are placed for illustration purpose only. Appearance of real component may differ.
Electromagnetic relay for DC (up to 320 V) and AC (up to 418 V 50..2400 Hz) circuits.
Rated currents and number of contacts
Type | Number of NO contacts | Number of NC contacts | Rated current per contact, A |
RNE 66 | 4 | 6 | 10 |
RNE 44 | 4 | 4 | 16 |
RNE 31 | 3 | 1 | 50 |
RNE 22 | 2 | 2 |
Control circuit voltage and coil resistance
DC control voltage, V | Coil resistance at 20 oC | |
Rated | Operational | |
12 | 10.8..14.2 | 21±2.1 |
24 | 21.6..28.4; 22..29 | 83±8.3 |
27 | 24..32 | 108±10.8 |
110 | 99..121 | 1460±146 |
220 | 198..242 | 5600±560 |
Technical parameters
Voltage drop on contacts (at current 0.5 A..rated), not more than, V | 0.6 |
Turn-on frequency, up to, hour-1 | 1200 |
Pick-up time, not more than, s | 0.04 |
Drop-out time, not more than, s | 0.02 |
Mechanical durability, switching cycles | 100000 |
Switching durability, switching cycles | 100000 |
Minimum switching current, A at 30 V at 20 V at 6 V |
0.001 0.5 |
Climate version | 1 |
Ambient air temperature, oC | all-climate |
Relative humidity at +40 oC, not more than | 98% |
Air pressure, gPa | 3040..1.3·10-6 |
Temperature variation, oC | -60..+85 |
Resistant to mold fungi, frost, dew, salt fog |
|
Sinusoidal vibration frequency (with acceleration up to 25 g), up to, Hz | 5000 |
Multiple mechanical impact acceleration (duration 2..10 ms), up to, g | 40 |
Single mechanical impact acceleration (duration 1..5 ms), up to, g | 150 |
Single mechanical impact acceleration (duration 0.2..1 ms), g | 1000 |
Linear acceleration, up to, g | 100 |
Acoustic noise frequency (at sound pressure up to 150 dB), Hz | 50..10000 |
Mass, not more than, kg | 0.225 |
Operational position | any |
Mounting method | screws on relay panel and nuts |
Wire mounting | rear, soldering |
Warranty, years | 25 |