Relays RPS-43 are hermetic polarized two-position, bistable, with two switching contacts, designed for commutation of electric circuits of direct and alternate current.
Technical characteristics.
Supply current - direct.
Isolation resistance between current conducting elements, current conducting elements and casing, MOm:
- in normal climatic conditions - 200
- at maximum temperature - 20
- in conditions of high humidity - 10
Alternate voltage, V:
in normal climatic conditions:
- between windings, between winding and casing - 500
- between contacts, between contacts and casing - 350
in conditions of high humidity:
- between windings, between winding and casing - 300
- between contacts, between contacts and casing - 210
Seal-in time, maximum 5 ms.
Relay weight, maximum 8 g.
Minimum shelflife in conditions of heated space, also mounted into protected equipment or in spare parts set- 20 years.