Home  /  Products  /  Switching devices  /  TKE 14PD1U

TKE 14PD1U

Switching devices TKE 14PD1U
* Pictures are placed for illustration purpose only. Appearance of real component may differ.

Electromagnetic relays for AC and DC circuits.

Relays are divided by: rated control voltage; operating current type; main contacts rated current; contact number and type; maximum allowed ambient air temperature; extra features

Annotation breakdown

[1st element] – rated control voltage: T – 27 V DC, P – 18 V DC, S – 115 V AC

[2nd element] – relay version: K – DC-operated switching relay; P – AC-operated switching relay

[3rd element] – main contacts rated current: letter – multiplicator:N – 0.1; E – 1; D – 10. Following number should be multiplied by the multiplicator

[ 1st digit] – 0 – the absence of independent NC contacts;

[2nd digit] – number of independent NO contacts; number+”P” – number of switching contacts

[*] – maximum ambient air temperature: 0 – 85 oC; 1 – 100 oC (in earlier versions OD – 85 oC; 1 – 100 oC; 1P – 150 oC)

[*][*] - extra features: G – sealed; A, B, M2 – upgraded versions

Main features

Relay is a device with switching contact groups operated by valve-type electromagnet.

Mounting method: wire mounting, soldering.

Relay is fastened by screws installed on the bottom of the cover.

Unsealed relays are ventilated through the cover holes, covered by the mesh.

Unsealed relays are subject to environmental impacts (humidity, temperature, air pressure). Sealed relays should be chosen to avoid that impacts.

In sealed relays switching contacts and some magnetic conductor details are enclosed in a separate welded compartment with dry air. In TKE21POGD relay the entire magnetic system with a coil is enclosed in that compartment

TKE22P1GB, TKE24P1GB, TKE26P1GB can be used together (making 2, 4 or 6 switching groups), have similar design and differ by dimensions and coil parameters

TKE22P1GA, TKE22PODGB can be used together (making 4 or 6 switching groups), have similar design and differ by dimensions and coil parameters.

SPE22PODGB, TPE22PODGB have similar design and differ by coil parameters and diode blocks for control current rectification.

TKN21POGM series 2, TKN21P1DG, TKE101ODG are for PCB mounting and should be fastened by epoxy adhesive and soldering.


Version

Design

Ambient air temperature, oC

Rated contact voltage, V

Contact voltage range, V

Contact current range, A

Control voltage range, V

Opearting mode

Number of contact pairs

Switching durability, cycles*

Mass, g

DC

AC 400Hz

AC 50..1100 Hz

DC

AC 50-1100 Hz

switching

front

TKE52PD1

non-sealed

-60..+100

27

16..30

20..220

-

0.05..5

24..30

-

Continuous

2

-

1·104

100

TKE54PD1

4

140

TKE56PD1

6

180

TKE52PK1

17.5..30

Short-time

2

100

TKE54PK1

4

140

TKE56PK1

6

180

TKD12PD1

0.1..10

24..30

Continuous

2

170

TKD12PK1

17.5..30

Short-time

TKN21PODGM series 2

sealed

-60..+85

0.05..150

5..134

0.00001..0.25

24..30

Continuous

1

5·104

2.2

TKN21P1DG

-60..+100

0.2..30

0.001..0.25

16.5..30

6.3

TKE101ODG

-60..+85

17..30

-

0.05..1

-

1

3·104

6.5

TKE21PODG

-60..+100

5..30

12..220

0.001..2

22..30

1

1·104

35

TKE22P1GB

-

12..220

24..30

2

50

TKE24P1GB

4

75

TKE26P1GB

6

100

TKE24P1GA

4

TKE26P1GA

6

125

TKE52PODGB

-60..+85

20..200

0.05..5

2

TKE52P1PGB

-60…+150

12..220

PKE52P1PGB

12-16

TPE22PODGB

-60..+85

0.05..2

-

32..40

60

SPE22PODGB

108..120

You can order TKE 14PD1U from us