Home  /  Products  /  Vacuum tubes  /  6D16D-R

6D16D-R

6D16D-R

UHFdiodes for impulse signal detection.

Case type: with metal-glass envelope, microminiature. Mass 3.5 g.

Main parameters (at Uf = 6.3 V)

Filament current, mA

260±40

Cathode impulse current (at Ua=60 V, τ=2 mks, f=50 kHz), mkA

≥600

Cathode reverse current (at Ua=-300 V), mkA

≤0.1

Rectified current (at Ua=80 V and Ra=3.5 kOhm), mA

≥8

Internal resistance, Ohm

≤300

Microphonic voltage (at Ra=10 kOhm), mV

≤1.5

Interelectrode capacitance, pF

anode-to-cathode

cathode-to-filament

≤2

≤6

Durability, h

≥2 000

Durability test

Cathode impulse current, mA

≥400

Operational limits

Filament voltage, V

6..6.6

Reverse voltage, V

450

Cathode-to-filament voltage, V

100

Cathode impulse current, A

2

Anode power dissipation, W

1

Operational frequency, MHz

3 000

Anode impulse power (at f=2000 MHz, τ=1mks, Q=1670), kW

2

Envelope temperature (near anode junction), oC

170

Vibratory loads

frequency, Hz

acceleration, g

5..2000

15

Multiple mechanical impacts acceleration, g

150

Single mechanical impact acceleration, g

500

Linear acceleration, g

100

Ambient air temperature, oC

-60..+125


You can order 6D16D-R from us