6Zh8
Abrupt curve pentode for intermediate and high frequency voltage amplification.
Case type: metal
Cathode type: indirect heated,oxide-covered
Technical parameters
Not less than | Rated | Not more than | |
Heater voltage, V | 6.3 | ||
Heater current, mA | 275 | 300 | 325 |
Anode current, mA | 2 | 3 | 4 |
1st grid reverse current, mkA | 0.5 | ||
2nd grid current, mA | 0.4 | 0.8 | 1.2 |
Cathode-to-heater leakage current, mkA | ±20 | ||
Anode current in initial point, mkA | 30 | ||
Emission current, mA | 60 | ||
1st grid thermocurrent, mkA | 1 | ||
Mutual conductance, mA/V | 1.3 | 1.65 | 2 |
Mutual conductance with underheat, mA/V | 0.8 | ||
Readiness time, s | 20 | ||
Capacitance, pF grid-to-cathode anode-to-cathode anode-to-grid | 4.9 5.2 | 6 7 | 7.1 8.8 0.005 |
Durability, h | 2000 | ||
Shelf life, years | 8 |
Operational limits
Heater voltage, V | 5.7..7 |
Anode voltage, not more than, V | 330 |
2nd grid voltage, not more than, V | 140 |
Cathode to heater voltage, not more than, V | ±100 |
Anode power dissipation, not more than, W | 2.8 |
2nd grid power dissipation, not more than, W | 0.7 |
Operational limits shouldn’t be achieved at 2 or more electrodes simultaneously and should not be exceeded. Maximum dissipation power is allowed on short-term only.