Home  /  Products  /  Vacuum tubes  /  TGI1-500/20

TGI1-500/20

TGI1-500/20

Gas-filled triode for impulse circuits. Filling – hydrogen. Cooling: anode heatsink - forced, air, 20 m3/h, grid heatsink – free cooling.

Case: metal-glass (RSh1-3), mass 3 kg.

Main parameters (at UF=6.3V, UA=20 kV, fA=1000 imp/sec, τA=2 mks, UG=400 V, τG=4 mks, SFE=100 V/mks)

Filament current, A

18..21

Anode current (impulse), A

≤500

Anode current (mean), A

≤1

Anode reverse voltage, kV

≤20

Anode current impulse to grid voltage impulse delay, mks

≤0.4

Periodical ignition instability (at UA=10 kV), mks

≤0.005

Durability, h

≥500

Durability criteria

anode current delay time constant, s

anode current impulse to grid voltage impulse delay change at UG change from 6 to 6.6 V, mks

≤120

≤0.3

Operational limits

Minimum

Maximum

Filament voltage, V

6

6.6

Anode forward voltage, kV

5

20

Anode reverse voltage, within 25 mks after anode current impulse, kV

-

5

Cathode heating time, min

5

-

Case temperature, oC

-

250

Anode circuit current impulse

anode current (amplitude), A

anode current (mean), A

frequency, imp/sec

duration, mks

front edge slope, A/mks

-

-

-

-

-

500

1

5000

10

2500

Grid circuit ignition impulse

voltage, V

duration, mks

front edge slope, V/mks

grid current (amplitude), A

400

3

500

3

-

6

2000

-