3I402
Gallium arsenide alloy-junction inverse diodefor sensors and mixing units.
Case type: metal-ceramic with flexible terminals.
Diode type is indicated on the label:
3I402A - OA
3I402B - OB
3I402V - OV
3I402G - OG
3I402D - OD
3I402E - OE
3I402I - OI
Mass not more than 0.15 g.
Electrical parameters
Constant forward voltage (at 2nd ascending arm current 0.1 mA), for 3I402A, 3I402B, 3I402V, 3I402G, not less than, V at T=+25oC at Tmax at T=-60 oC | 0.6 0.4 0.6 | |
Constant forward voltage (at 2nd ascending arm current 0.2 mA), for 3I402D, 3I402E, not less than, V at T=+25oC at Tmax at T=-60 oC | 0.6 0.4 0.6 | |
Constant forward voltage (at 2nd ascending arm current 0.4 mA), for 3I402I, not less than, V at T=+25oC at Tmax at T=-60 oC | 0.6 0.4 0.6 | |
Constant reverse voltage (at reverse current 1 mA),for 3I402A, 3I402B, 3I402V, 3I402G, not more than, V at T=+25oC at Tmax at T=-60 oC | 0.25 0.29 0.35 | |
Constant reverse voltage (at reverse current 2 mA),for 3I402D, 3I402E, not more than, V at T=+25oC at Tmax at T=-60 oC | 0.25 0.29 0.35 | |
Constant reverse voltage (at reverse current 4 mA),for 3I402I, not more than, V at T=+25oC at Tmax at T=-60 oC | 0.25 0.29 0.35 | |
Differential resistance (at maximum reverse current 100 mA), not more than for 3I402A for 3I402B for 3I402V | 18 16 14 |
Operational limits
Constant reverse current, mA for 3I402A, 3I402B, 3I402V, 3I402G for 3I402D, 3I402E for 3I402I | 2 4 8 |
Ambient air temperature, oC | -60..+100 |