Home  /  Products  /  Switching devices  /  REK-60

REK-60

* Pictures are placed for illustration purpose only. Appearance of real component may differ

DC-controlled low-frequency monostable relay with 2 switching contacts. Designed for commutation in DC and AC circuits.

Relay is sealed in a microminiature metal case. Climate versions: boreal (RVIM.647612.027-01..-04) and all-climate (RVIM.647612.027-05..-09) in accordance with GOST 15150-69

Mass, not more than

3.1 g

Degree of leakage

no mark

“Δ”mark

“Δ6” mark

1,33·10-7 m3·Pa·s-1 (10-3 mmHg·s-1)

6.67·10-9 m3·Pa·s-1 (5·10-5 mmHg·s-1)

1,33·10-10 m3·Pa·s-1 (10-6 mmHg·s-1)

Electrical parameters and switching modes

Contact resistance at 6±1 V and 10 ±1 mA, not more than

0.3 Ohm

Insulation strength

between conductive parts

between conductive parts and case

200 V

300 V

Insulation resistance in normal conditions

1000 MOhm

Coil electric parameters and timing

Version

Coil voltage, V

Coil resistance, Ohm

Pick-up current, not more than, mA

Drop-out current, not less than, mA

Time, not more than, ms

Bouncing time, not more than, ms

On

Off

On

Off

RVIM.647612.027, -05

27

1900+120/-380

9.0

1.8

3.5

1.5

2.0

1.2

RVIM.647612.027- 01, -06

18

800±120

13.3

2.6

RVIM.647612.027- 02, -07

12

270±40

24.1

4.8

RVIM.647612.027- 03, -08

6

65+6.5/-10

54.6

11.0

RVIM.647612.027- 04, -09

4

36±3.6

64.3

13.0

Switching modes

Switching current, A

Switching voltage, V

Current type

Load type

Switching frequency, not more than, Hz

Number of switching cycles

Total

incl. at maximum temperature

0.01..0.25

6..30*

DC

noninductive

10

105

5·104

0.25..0.5

6..30*

DC

noninductive

10

5·104

2.5·104

0.5..1

6..30*

DC

noninductive

3

104

5·103

0.01..0.15

6..120**

AC 50-1100 Hz

noninductive

10

5·104

2.5·104

0.01..0.25

6..30*

DC

inductive τ≤0.015 s

3

104

5·103

0.25..0.5

6..30*

DC

inductive τ≤0.015 s

1

5·103

2.5·103

0.01..0.15

6..120**

AC 50-1100 Hz

inductive cos?≥0.3

3

104

5·103

10-6..10-3

0.05..10

DC, AC 50-1100 Hz

noninductive

10

1.5·105

7.5·104

10-3..0.05

3..36

DC

noninductive

10

104

5·103

10-3..0.06

3..36

DC

inductive τ≤0.015 s

5

104

5·103

* voltage increase up to 36 V allowed if switching power value remains the same

**root-mean-square voltage

Relay operation modes

Version

Coil voltage, V

Ambient air temperature, oC

Air pressure, Pa(mmHg)

Coil maximum temperature live time, h

Pulse ratio, not less than

Total coil maximum temperature live time, h

RVIM.647612.027, -05

27+7/-4*

-60..+85

8.4·104..3.04·105 (630-2280)

50

-

100

-60..+50

666..8.4·104

(5-630)

8.3·10-3

9

50

-60..+50

1.33·10-6..666 (10-8..5)

2.7·10-3

11

5 / 500**

RVIM.647612.027-01, -06

18±2

-60..+85

8.4·104..3.04·105 (630-2280)

100

-

100

-60..+50

666..8.4·104

(5-630)

8.3·10-3

9

50

-60..+50

1.33·10-6..666 (10-8..5)

2.7·10-3

11

5 / 500**

RVIM.647612.027-02, -07

12+4/-2

-60..+70

8.4·104..3.04·105 (630-2280)

50

-

100

-60..+50

666..8.4·104

(5-630)

8.3·10-3

9

50

-60..+50

1.33·10-6..666 (10-8..5)

2.7·10-3

11

5 / 500**

RVIM.647612.027-03, -08

6+2/-1

-60..+60

8.4·104..3.04·105 (630-2280)

100

-

100

-60..+50

666..8.4?104

(5-630)

8.3·10-3

9

50

-60..+50

1.33?10-6..666 (10-8..5)

2.7·10-3

11

5 / 500**

RVIM.647612.027-04, -09

4±0.5

-60..+85

8.4·104..3.04·105 (630-2280)

100

-

100

-60..+50

666..8.4·104

(5-630)

8.3·10-3

9

50

-60..+50

1.33·10-6..666 (10-8..5)

2.7·10-3

11

5 / 500**

* allowed voltage 27+7/-5 at maximum ambient air temperature +70 oC

** for “Δ” and “Δ6” versions

Operational limits

Sinusoidal vibration

frequency, Hz

displacement amplitude, mm

frequency, Hz

acceleration amplitude, m/s2

frequency, Hz

acceleration amplitude, m/s2

1..50

1.5

50..1500

150

1500..3000

200

Broad-band random vibration

frequency, Hz

acceleration mean-square value, up to, m/s2

acceleration spectral density, up to, m2/s4/Hz

20..2000

100

5

Single mechanical impact*

acceleration, up to, m/s2

duration, ms

number of impacts

5000 (1500)

0.1..2 (1..5)

3 (9)

Multiple mechanical impacts

acceleration, up to, m/s2

duration, ms

750 (350)

0.1..2 (1..5)

Linear acceleration, up to, m/s2

750

Acoustic noise

frequency, Hz

sound-pressure level, not more than, dB

50..10000

140

Temperature variations,oC

-60..+85

Relative humidity at +35 oC

98%

Rime frost and dew

Static dust, salt fog and mold fungi (for REC60V)

Minimum shelf life and life time, years

no mark

“Δ”mark

“Δ6” mark

15

20

25

You can order REK-60 from us