Home  /  Products  /  Switching devices  /  RES-43 RS4.569.203

RES-43 RS4.569.203

Switching devices RES-43 RS4.569.203
* Pictures are placed for illustration purpose only. Appearance of real component may differ.

Low-current monostable non-polarized Reed relay with 2 normally open contacts. Relay is based on KEM2 Reed capsule and can be used for DC and AC (up to 10 kHz) circuits.

Climate version: boreal in accordance with GOST 16121-86 and KSh0.450.014 TU

Technical parameters

Version

Coil layout

Operating voltage, V

Coil resistance, Ohm

Pick-up voltage, not more than, V

Drop-out voltage, not less than, V

RS4.569.201

A-B, V-G

12+2.0/-1.2

230±34.5

5.5

1.0

serial AG (BV)

460±69.0

5.5

1.0

Parallel AV-BG

115±17.2

2.8

0.5

RS4.569.202

A-B

27±5.0

1200±180

11.5

2.0

V-G

27±3.0

1200±180

14.0

2.5

Serial AG (BV)

27+5.0/-4.0

2400±360

13.0

2.5

Parallel AV-BG

27+3.0/-7.0

600±90.0

6.5

1.2

RS4.569.203

A-B

10±1.0

760±114

5.6

1.1

RS4.569.204

A-B

48±5.0

7500±1500

23

3.0

Technical characteristics

Contact resistance, not more than, Ohm

0.2

Pick-up time, not more than, ms

1.3

Insulation resistance between live parts, live parts and case, not less than, MOhm

in normal conditions

at maximum temperature

500

20

Insulation resistance at increased humidity, not less than, MOhm

between contacts, contacts and case, contacts and coils

between coils, coils and case

10

5

Insulation strength in normal conditions, V

between live parts and case, between contacts, between contacts and coils

between coils

between each reed capsule terminals

500

300

200

Insulation strength at increased humidity, V

between live parts and case, between contacts, between contacts and coils

between each reed capsule terminals

300

200

Insulation strength at diminished air pressure, V

between live parts and case, between contacts, between contacts and coils

180

Mass, not more than, g

15


Switching modes

Switching ranges

Current type

Load type

Switching frequency, Hz

Number of switching cycles

Current, A

Voltage, V

total

at +85 oC

5·10-6..10-3

0.05..30

DC, AC

Noninductive

100

108

5·106

0.01..0.1

0.05..30

107

2·106

0.1..0.25

0.05..30

106

2·105

0.02..0.03

150..180

106

2·105

0.001..0.01

0.05..30

107

2·106

0.01..0.1

0.05..30

DC

Inductive, τ≤7 ms

10

105

5·104

0.01..0.1

0.05..30

5·104

2.5·104

Operational conditions

Ambient air temperature, oC

-60..+84

Air pressure, GPa (mmHg)

1.33·10-4..2.13·105 (10-60..1.6·103)

Relative humidity at +35 oC

98%

Vibratory loads

frequency, Hz

amplitude, mm

frequency, Hz

acceleration, m/s2 (g)

5..50

1.5

50..3000

147 (15)

Single mechanical impacts

number of impacts

acceleration, m/s2 (g)

9

1470 (150)

Multiple mechanical impacts

number of impacts

acceleration, m/s2 (g)

number of impacts

acceleration, m/s2 (g)

4000

735 (75)

10000

343 (35)

Impact strength

number of impacts

acceleration, m/s2 (g)

60

980 (100)

Linear acceleration, m/s2 (g)

980 (100)

You can order RES-43 RS4.569.203 from us