Home  /  Products  /  Switching devices  /  RES-44 RS4.569.251

RES-44 RS4.569.251

Switching devices RES-44 RS4.569.251
* Pictures are placed for illustration purpose only. Appearance of real component may differ.

Two-position monostable reed relay for DC and AC (up to 10 kHz) circuits. Relay is compliant with GOST16121-86 and KSh0.450.014TU

Operational limits

Relative humidity at +35 oC

98%

Air pressure, Pa

133·10-6..213·103

Sinusoidal vibration

frequency, Hz

amplitude, mm

frequency, Hz

acceleration, m/s2

5..50

1.5

50..2000

150

Single mechanical impacts (up to 9) acceleration, m/s2

750

Multiple mechanical impacts (up to 4000) acceleration, m/s2

350

Impact resistance (up to 60 impacts) acceleration, m/s2

1000

Linear acceleration, m/s2

1000

Operation modes

Relay type

Modification

Operational voltage, V

Ambient air temperature, oС

RES44

RS4.569.151

RS4.569.252

27±3

27±5

-60…+85

27+5-4

24±4

-60…+100

-60…+70

Commutation

Type

Modification

Type and number of contacts

Coil

Voltage,V

Time,ms

Coils

Connecting

Resistance,Ohm

Actuation, not more

Release, not less

Actuation, not more

Release, not less

RES42

RS4.569.151
RS4.569.152

1 NC

820±123 4000+600-800

6,5

14

1,2

3

1

0,3

А —

Durability

Commutation mode

Load type

Current type

Frequency,
Hz, not more

Number of commutation cycles

Current, A

Voltage on open contacts,
V

total

incl. at max.temperate

5·10-6-10-3
10-2-10-1

5·10-2-30

active

DC

AC

100

108

107

5·106

2·106

10-1-2,5·10-1

106

2·105

2·10-2-3·10-2

150-180*

10-3-10-2

5·10-2-30

107

2·106

10-2-10-1

10-1-2·10-1

inductive,
t ≤ 0,015 s

DC

10

105

5·104

5·104

2,5·104

Technical parameters

Coil power supply current type

DC

Insulation resistance between live elements, between live elements and case, not less than, M?

in normal conditions

at maximum temperature (after coil being in on-state)

at increased humidity

between contacts, contacts and coils, contacts and case

between coils, coils and case

500

20

10

5

Proof voltage, V

in normal conditions:

between live elements and case, magnetic-reed contacts, contacts and coils

between coils

between magnetic-reed contacts terminals

at increased humidity:

between live elements and case, magnetic-reed contacts, contacts and coils, coils

between magnetic-reed contacts terminals

at diminished air pressure (between live elements, live elements and case, contacts)

500

300

200

300

200

180

Total or continuous on-state time, h

100

Contact material

gold

Contact resistance, Ohm

0,2

Mass, not more than

18 g

Particular parameters

Relay type

Version

Number of contacts

Coil

Voltage, V

Time, ms

Coil desighation

Connection

Resistance, Ohm

Pick-up, not more than

Drop-out, not less than

Pick-up, not more than

Drop-out, not more than

RES44

RS4.569.252

3

I

II

900±135

15

13.5

14

2.5

2

2.2

1

0.3

A — B

V — G

serialI+II

1800±270

1.3

0.5

AG (BV)

parallelI II

450±67.5

7

1.1

1

AV — BG

Durability

Switching modes

Load type

Current type

Switching frequency, not more than, Hz

Number of switching cycles

Allowed current, A

Open contacts voltage, V

total

incl. at maximum temperature

5·10-6-10-3
10-2-10-1

5·10-2-30

noninductive

DC, AC

100

108

107

5·106

2·106

10-1-2.5·10-1

106

2·105

2·10-2-3·10-2

150-180*

10-3-10-2

5·10-2-30

107

2·106

10-2-10-1

10-1-2·10-1

inductive,
t ≤ 0,015 s

DC

10

105

5·104

5·104

2.5·104

* maximum AC voltage 130 V