Vacuum tubes
Pulse modulated thyratron ТGI1-500/16 is designed for work in pulse systems.
Application areas: electrophysical installations, laser power supplies, medical hardware, radars.
Filling – hydrogenic.
Design – metal-ceramic.
Weight- 700 g.
Nominal electric characteristics of ТGI1-500/16:
Heating current ...... 13-17 А
Anode current (impulse amplitude) ...... maximum 500 А
Anode current (average value) ...... maximum 0,5 А
Anode reverse voltage ...... maximum 16 kV
Heating voltage ...... 6,3 V
Periodic lightning instability...... maximum 0,005 mcs
Heating voltage...... 6,3 V
Voltage drop between anode and cathode in pulse ...... maximum 250 V
Servicehours...... minimum500 h
Operational limits:
Heating voltage ...... 6,0-6,6 V
Anode direct voltage ...... maximum 16 kV
Anode circuit impulse:
- anode current (amplitude value) ...... 15-500 А
- anode current (average value) ...... maximum 0,5 А
- spacing frequency ...... maximum 4000 pul/s
- width ...... 0,5-10 mcs
- transconductance pulse rise ...... maximum 2000 А/mcs
Circuit igniter pulse parameters:
- voltage amplitude...... minimum1000 V
- current amplitude ...... minimum 2,5 А
- pulse width ...... 3-7 mcs
- pulse front transconductance ...... 1000-2500 mcs